Four CE Events Highlighting the Latest Updates in Amblyopia and Glaucoma Management

Woo U continues to bring eye care professionals valuable clinical insights through its continuing education (CE) events. Across four educational sessions, expert speakers explored the latest updates in amblyopia management, dry eye disease in glaucoma patients, glaucoma surgery co-management, and intraocular pressure (IOP) and corneal hysteresis.

These sessions covered current research, treatment approaches, clinical considerations, and practical strategies to help optometrists enhance patient care.

Amblyopia Management and Current Updates

Speakers: Dr. Valerie Lam and Dr. Stephanie Hwang

The session began by redefining amblyopia as a neurodevelopmental disorder impairing unilateral or bilateral visual function, often caused by high refractive error, anisometropia, strabismus, visual deprivation, or a combination of these conditions.

The speakers discussed the types and causes of amblyopia in detail, including refractive, strabismic, deprivation, and combination amblyopia. They also explored traditional treatments such as refractive correction and patching or atropine, alongside current and emerging treatments and therapies.

The presentation also covered their amblyopia checklist, case studies, and current research, providing attendees with practical clinical insights into the management of amblyopia.


Amblyopia Management and Current Updates

Speaker: Kaleb Abbott, OD, MS, FAAO, FOWNS

This session explored the relationship between glaucoma management and ocular surface disease, highlighting how glaucoma medications can contribute to dry eye symptoms and compromise patient comfort.

Key takeaways included:

  • Ocular surface disease is common in glaucoma patients. More than half of patients with glaucoma experience dry eye disease, with severity increasing alongside the number of medications, frequency of instillation, and duration of treatment.

  • Glaucoma medications themselves can contribute to ocular surface disease. Beyond preservative toxicity, active ingredients can disrupt the tear film, impair meibomian gland function, promote inflammation, and compromise corneal epithelial health.

  • The preservative benzalkonium chloride (BAK) is a major contributor to ocular surface toxicity. Chronic exposure can damage epithelial cells, destabilize the tear film, and cause corneal nerve toxicity, potentially leading to neurotrophic keratitis.

  • Preservative-free glaucoma medications offer comparable IOP reduction with better ocular surface tolerability. Corneal staining was reported in 25.6% of patients using preserved drops compared with only 8.9% using preservative-free formulations.

  • Don't overlook prostaglandin-associated periorbitopathy. Prostaglandin analogs can cause orbital fat atrophy, deepening of the upper eyelid sulcus, ptosis, and enophthalmos. Bimatoprost carries a particularly high risk, and switching to another prostaglandin may not reverse these changes, requiring a change in medication class.

  • Not all medication-related ocular irritation is dry eye. Brimonidine allergy can develop months or even years after treatment initiation, while topical beta-blockers and netarsudil have been associated with punctal stenosis and canalicular narrowing.

  • Consider SLT earlier to reduce topical medication burden. In the LiGHT trial, approximately 74% of patients treated with SLT maintained drop-free IOP control at three years, potentially reducing medication-related ocular surface complications.

  • Ocular surface recovery takes time. Improvement following discontinuation of BAK-containing medications may take 8–12 weeks. Transitioning to preservative-free formulations can improve comfort while maintaining IOP control.

  • Poor medication tolerability can translate into poor glaucoma control. Ask patients directly: “Do you ever skip your glaucoma drops because of burning, redness, or discomfort?” Identifying these barriers can help improve adherence.

  • Treat the ocular surface, not just the IOP. Ocular surface disease can compromise patient comfort, medication adherence, and the reliability of visual field and OCT testing. Optimizing ocular surface health is an important component of successful glaucoma management.


The Co-Management of Glaucoma Surgery

Speaker: Elizabeth D. Muckley, OD, FAAO

This CE event focused on the evolving role of glaucoma surgery, including minimally invasive glaucoma surgery (MIGS), selective laser trabeculoplasty (SLT), and the importance of effective co-management between optometrists and surgeons.

Key takeaways included:

  • Glaucoma surgery is no longer reserved for advanced disease. With expanding MIGS options, earlier intervention should be considered for inadequate IOP control, poor medication adherence, or continued structural or functional progression.

  • Set realistic surgical expectations. Glaucoma surgery aims to slow or prevent further vision loss, not restore lost vision. Patients must understand that they may still require IOP-lowering medications postoperatively.

  • Gonioscopy is essential for surgical decision-making. Angle assessment is essential in correctly diagnosing the type of glaucoma and helps determine MIGS eligibility as well as identify angle-closure risk. Repeat gonioscopy periodically, as angle anatomy can change over time.

  • SLT is an effective first-line or adjunctive treatment. SLT typically reduces IOP by 20–25%, and the LiGHT trial supports a laser-first approach for ocular hypertension and open-angle glaucoma.

  • Direct SLT (DSLT) offers a contact-free approach to trabeculoplasty. Unlike conventional SLT, DSLT delivers laser energy transconjunctivally without a gonioscopy lens. In the GLAUrius trial, DSLT demonstrated comparable IOP reduction to conventional SLT at 12 months, with 62% of patients being medication-free at one year.

  • Not all MIGS procedures achieve the same IOP reduction. The magnitude of IOP lowering depends on the targeted outflow pathway. Trabecular bypass and canal-based procedures are generally best suited for mild to moderate glaucoma, while subconjunctival filtration procedures such as the XEN Gel Stent can achieve greater IOP lowering results.

  • Consider MIGS when referring glaucoma patients for cataract surgery. Combining MIGS with cataract extraction may further reduce IOP and medication burden. When appropriate, refer to a surgeon experienced in both procedures.

  • Avoid prematurely discontinuing glaucoma medications after MIGS. IOP-lowering effects may take several weeks to develop. Adjust medications based on postoperative IOP and the patient's individualized target pressure.

  • Postoperative gonioscopy is important in MIGS co-management. Evaluate stent position and patency, and assess for peripheral anterior synechiae or other causes of inadequate IOP reduction, particularly when the anticipated IOP reduction is not achieved.

  • Bleb-forming procedures require careful postoperative monitoring. XEN outcomes depend on maintaining bleb function and minimizing fibrosis, often requiring prolonged corticosteroid therapy and occasionally bleb needling.

  • Effective glaucoma co-management depends on communication. Understand the surgeon's postoperative protocols, medication preferences, and potential complications to ensure safe, coordinated patient care.


All Things IOP and Corneal Hysteresis: Updates in Modern Glaucoma Care

Speaker: Nate Lighthizer, OD, FAAO

This session explored the role of intraocular pressure (IOP) and corneal hysteresis (CH) in modern glaucoma care, highlighting how corneal biomechanics can provide additional information when assessing glaucoma risk and progression.

Key takeaways included:

  • IOP does not define glaucoma, but it remains our most important modifiable risk factor. Glaucomatous damage can occur at statistically normal IOP levels, making optic nerve assessment, OCT, and visual field testing essential regardless of measured pressure.

  • Corneal hysteresis (CH) provides valuable information beyond central corneal thickness (CCT). CH reflects the cornea's ability to absorb shock and dissipate energy. A thick cornea does not necessarily have high CH, nor does a thin cornea necessarily have low CH.

  • Low corneal hysteresis (CH) is an important predictor of glaucoma progression. Lower CH is independently associated with faster visual field deterioration, even after accounting for IOP and central corneal thickness (CCT). Values below 10 mmHg are generally associated with increased risk, with CH below 8 mmHg considered particularly concerning.

  • Each 1 mmHg decrease in CH was associated with a 0.25% faster annual rate of visual field index loss. In the prospective DIGS study, CH was more strongly associated with visual field progression than CCT, highlighting its value in glaucoma risk assessment.

  • The impact of IOP on glaucoma progression may be greater in eyes with low CH. Patients with lower CH appear more susceptible to IOP-related damage, emphasizing the importance of considering corneal biomechanics when assessing risk and establishing treatment goals.

  • Corneal hysteresis can help identify higher-risk glaucoma suspects. Lower CH has been associated with an increased likelihood of conversion to glaucoma and may help guide decisions regarding treatment initiation and monitoring frequency.

  • Baseline CH may help predict the magnitude of IOP reduction with prostaglandin therapy. Studies suggest that eyes with lower pretreatment CH may experience a greater percentage reduction in IOP following treatment with prostaglandin analogs.

  • Corneal-compensated IOP (IOPcc) provides an additional perspective on IOP. Unlike Goldmann applanation tonometry, IOPcc is designed to reduce the influence of corneal biomechanical properties and may provide useful complementary information when evaluating glaucoma risk.

  • Corneal hysteresis is not a fixed measurement. CH can change with IOP reduction and tends to decrease slightly with age. Interpret CH in the context of current IOP, treatment status, and the patient's overall glaucoma risk profile.

  • Rebound tonometry offers a convenient and reliable alternative to Goldmann applanation tonometry (GAT). Handheld devices, including the iCare and Tono-Vera, provide IOP measurements that are generally comparable to GAT.

  • Consider home tonometry when office IOP measurements don't explain glaucoma progression or in cases of presumed NTG. The iCare HOME2 is designed for patient-operated home monitoring and can help identify diurnal IOP fluctuations and pressure spikes missed during routine office visits, particularly in patients progressing despite apparently well-controlled IOP.


Continuing Education That Supports Better Patient Care

Across these four CE events, Woo U brought together experienced speakers to share current research, clinical findings, treatment approaches, and practical considerations in eye care.

From understanding the neurodevelopmental aspects of amblyopia to addressing ocular surface disease in glaucoma patients, improving glaucoma surgery co-management, and incorporating corneal biomechanics into glaucoma risk assessment, each session offered valuable insights for clinical practice.

Thank you to Dr. Valerie Lam, Dr. Stephanie Hwang, Kaleb Abbott, OD, MS, FAAO, FOWNS, Elizabeth D. Muckley, OD, FAAO, and Nate Lighthizer, OD, FAAO, for sharing your knowledge and expertise with Woo U.

And thank you to all the eye care professionals who joined us and continue to make lifelong learning part of their practice!

Learn, connect, and grow with Woo U. Continue exploring our free continuing education opportunities at woou.org.

Next
Next

Woo u Wisdom: Key Clinical Insights, Pearls & Practical Takeaways from Woo U CE